Home
Poly Foam
Acoustical
Fireproofing
Roofing


 

Spray-On Acoustical

Frantl lndustries, inc. spray-on acoustical system applies a strong and durable acoustical treatment to provide exceptionally high noise reduction. The resilient fibers of spray-on acoustical systems absorb sound energy instead of reflecting it. This reduces reverberation time, making speech much more intelligible.

Frantl's acoustical sytems are sprayed-applied to virtually any type of substrate to achieve a strong and durable finish. Typical installations include: schools (gymnsaiums), churches, auditoriums, industrial plants, libraries, detention facilities, hotels, condominiums, wastewater facilities(blower rooms) and convention centers.

Ceilings * Walls * Skylights * Parking Garages * Attics * Adheres to most surfaces * Rapid installation * Minimizes company downtime

                

 






Celbar Spray-On Systems

System Description
Celbar is a blend of specially prepared cellulose fibers, organic in nature, treated with adhesive and fire resistant chemicals. When sprayed in place, the interlocking fibers result in a mass which produces excellent sound and'thermal properties.
Celbar is pneumatically spray-applied in wall and floor/ceiling cavities to form a monolithic coating. This process seals cracks and holes in the wallboard, around plumbing and electrical outlets, vent ducts and other irregularities. There are no compressed areas or voids to allow sound leaks, R value reductions, or air infiltration.
Performance Where It Counts
Celbar provides superior sound transfer control demanded by building designers, owners and occupants. Celbar assemblies perform closer to lab tested STC ratings in the field than do other conventional batt and sound board systems. This is due to the complete coverage and the sealing action of Celbar.
Laboratory tests have proven that Celbar produces significantly higher STC values than other identically constructed wall systems

Physical Properties
Thermal Properties
           Thickness      1.0"     2.5"     3.5"
           R-Value         3.8      9.5     13.3

Fire Hazard Classification Underwriters Laboratories; Reference #R-5499.

Listings
-ICBO-Approval Number 2262
-Southern Building Code-Approval Number 9566
-HUD-FHA-VA-Permits the use ofCelbar in projects they finance-based on Celbar's compliance with UMB-80

ASTM E-119 Fire Rating - One Hour
Celbar has been tested in accordance with ASTM E-119 including hose stream test and is accepted for use in fire-rated wall assemblies as a one hour wall.