Roof Insulation
Powerfoam EPS roof insulation is a reliable cost effective product for use in all roofing systems.
-
Standard Flat
-
Tapered
-
Composite
-
Flute Filler
-
Crickets |
-
Vented Composites
-
Composite Tapered
-
Specialty Lamination
-
Saddles |
All products are manufactured to meet the specific needs of any job. * UL * FM * ICBO * BOCA * SBCCI * ASTM C 578 *
Return to Index |
 |
 |
 Geofoam
Geofoam is an all-purpose expanded polystyrene foam used in major construction throughout the United States, Europe and the world.
Geofoam is a solution to some of construction's toughest problems. Settlement, utility crossings, insulation and drainage are all problems solved by Geofoam's versatility.
Geofoam has been used all over the world on some of the biggest construction projects ever undertaken.
|
Uses for Geofoam:
|
-
Lightweight Fill
-
Road Embankments
-
Concrete Platforms
-
Dike Repair
-
Roof Top Landscaping
-
Floating Slabs |
-
Retaining Walls
-
Abutment Backfill
-
Slope Stabilization
-
Pavement Insulation
-
Frost Protected Shallow Landscapes
| Return to Index |
 |
 |
|
Foil-Faced Sheathing
POWERFOAM's commodity grade foil-faced sheathing is a highly efficient way to help homeowners and builders affordably meet model energy codes and HUD/FHA R-19 (U=.05) WALL STANDARDS.
Using standard R-13 batts with 2" x 4" framing construction Powerfoam foil-faced sheathing can help you pinpoint the exact R-value you wish to achieve, thus eliminating the need for expensive R-19 glass fiber batts and 2" x 6" framing.
The selection of the most economical thickness of POWERFOAM foil-faced sheathing depends on several factors including exterior finish. This can further reduce construction costs.
Advantages
INSTALLATION INSTRUCTIONS
POWERFOAM SHEATHING is designed for vertical installation over the exterior side of the studs using 7/16" head roofing nails 4" on center or 3/4" crown staples 8" on center. Staples should be used with 50 pounds pressure. Fastener should be 2" or, at least 1" longer than thickness of the sheathing.
POWERFOAM SHEATHING is nonstructural and must be coner braced with steel strapping or let-in bracing. (See cut away drawing)
POWERFOAM SHEATHING must be fully protected on the inside of the building by a thermal barrier equivalent. This requirement includes, but is not limited to garages, crawl spaces and basement walls.
|
THICKNESS |
SHEET SIZE |
UNFACED R-VALUE |
FOIL FACED SYSTEM R-VALUE |
SHEETS/ BUNDLE |
SQ FT/ BUNDLE |
EXTERIOR FINISH |
RECOMMENDED THICKNESS |
| |
|
|
1/2" AIR SPACE |
3/4" AIR SPACE |
|
|
|
|
|
1/2" 3/4" 1"
|
4' x 8' 4' x 8' 4' x 8'
|
1.6 2.3 3.1
|
4.1 4.8 5.6
|
4.3 5.0 5.8
|
24 16 12
|
768 512 384
|
Brick Veneer Aluminum Lap Aluminum Lap w/EPS backer Wood Lap Plywood Panel |
1/2" 1" 1/2" 3/4" 1" |
Return to Index
|
 |
|
Premium Grade Foil-Faced Sheathing
POWERFOAM's premium grade foil-2-side sheathing is a highly efficient way to help home owners and builders affordably meet model energy codes and HUD/FHA R-19 (U=.05) WALL STANDARDS.
Using standard R-13 batts with 2" x 4" framing construction Powerfoam foil-faced sheathing can help you pinpoint the exact R-value you wish to achieve, thus eliminating the need for expensive R-19 glass fiber batts and 2" x 6" framing.
The selection of the most economical thickness of POWERFOAM foil-faced sheathing depends on several factors including exterior finish. This can further reduce construction costs.
Use the following tables to help your determine whats best for your your individual project.
Advantages
INSTALLATION INSTRUCTIONS
POWERFOAM SHEATHING is designed for vertical installation over the exterior side of the studs using 7/16" head roofing nails 4" on center or 3/4" crown staples 8" on center. Staples should be used with 50 pounds pressure. Fastener should be 2" or, at least 1" longer than thickness of the sheathing.
POWERFOAM SHEATHING is nonstructural and must be coner braced with steel strapping or let-in bracing. (See cut away drawing)
POWERFOAM SHEATHING must be fully protected on the inside of the building by a thermal barrier equivalent. This requirement includes, but is not limited to garages, crawl spaces and basement walls.
|
THICKNESS |
SHEET SIZE |
UNFACED R-VALUE |
FOIL FACED SYSTEM R-VALUE |
SHEETS/ BUNDLE |
SQ FT/ BUNDLE |
EXTERIOR FINISH |
RECOMMENDED THICKNESS |
| |
|
|
1/2" AIR SPACE |
3/4" AIR SPACE |
|
|
|
|
|
1/2" 3/4" 1"
|
4' x 8' 4' x 8' 4' x 8'
|
2.0 3.0 4.0
|
4.5 5.5 6.5
|
4.7 5.7 6.7
|
24 16 12
|
768 512 384
|
Brick Veneer Aluminum Lap Aluminum Lap w/EPS backer Wood Lap Plywood Panel |
1/2" 1" 1/2" 3/4" 1" |
Return to Index |
 |
 |
Cavity Wall and Masonry
Powerfoam Cavity Wall and Masonry Insulation provides great insulation with permanent high R-value for new construction and remodeling.
It is all available in standard and custom sizes and has excellent physical and dimensional stability to meet the requirements of any job.
Lightweight and easy to install, Powerfoam sheathing insulation comes with a variety of facers and has no CFCs or HFCFs, making it one of the most environmentally friendly insulations on the market today.
Code Compliance: Powerfoam complies with the following codes and approvals: ICBO - BOCA - SBCCI - HUD - FHA - Bulletin # 71
|
PRODUCT INFORMATION Foil Faced Insulation |
|
THICKNESS |
INSTALLED |
SHEET SIZE |
SQ FT/SHEET |
SHEETS/PACKAGE |
SQ FT/ PACKAGE |
|
3/4" |
5.6 |
16" x 96" 24" x 96" 48" x 96" |
10.6 16.0 32.0 |
48 32 16 |
512 512 512 |
|
1" |
6.7 |
16" x 96" 24" x 96" 48" x 96" |
10.6 16.0 32.0 |
36 24 12 |
384 384 384 |
|
1 1/2" |
8.8 |
16" x 96" 24" x 96" 48" x 96" |
10.6 16.0 32.0 |
24 16 8 |
256 256 256 |
|
2" |
11.0 |
16" x 96" 24" x 96" 48" x 96" |
10.6 16.0 32.0 |
18 12 6 |
192 192 192 |
INSTALLATION INSTRUCTIONS
Powerfoam sheathing installation for masonry cavity walls: Place insulation between wall ties with long edge horizontal and ends and edges butted. Install insulation against back-up wall allowing 1/2" minimum air space between insulation and outer wall. Cut insulation with saw or sharp knife to fit tightly around vents. Louvers, pipes, conduit and other wall penetrations.
Powerfoam sheathing installation for masonry furred walls: Erect insulation vertically on concrete and block walls and fasten to substrate through wood or metal furring channels, spaced 24" o.c. maximum. Fasteners for furring should be a maximum of 12" on center. Install minimum of 12" gypsum board over insulation.
Return to Index
|
 |
 |
Packaging Foam
Powerfoam has been manufacturing and supplying expanded polystyrene foam to the packaging industry for over 15 years.
Standard or custom sizes are available through Powerfoam and delivered throughout the South Central United States.
Box liners, order separators or fill pieces are available in a wide range of densities and manufactured to the highest quality standards of the industry.
Small blocks are available for jobs that require a large number of individual sizes and cost is of particular importance.
Standard or custom sizes are available through Powerfoam and delivered throughout the South Central United States.
Return to Index |
 |
 |
Expanded Polystyrene Blocks
Powerfoam Insulation's EPS facility has been providing high quality expanded polystyrene blocks to the EPS fabrication industry for more than 15 years.
The Powerfoam EPS block is 37" x 49.5" x 195" and available in a wide range of densities from 0.70 pcf to 1.80 pcf to conform to any fabrication requirement.
Powerfoam can provide blocks untrimmed for maximum yield or custom cut for individual job requirements.
Powerfoam insulation uses only the highest quailty modified expanded polystyrene for its blocks. This, in combination with vacuum molding and technologically advanced batch expansion insures dry, well fused block foam for the quailty workmanship demanded by fabricators and end users.
Return to Index |
 |
 |
EIFS Foam
Powerfoam has been supplying foam to the Exterior Insulation and Finish System (EIFS) industry for 15 years.
RADCO approved (Listing #1219), Powerfoam EIFS foam is aged to insure dry and dimensionally stable foam.
Powerfoam is specificed by all the major brands of EIFS manufacturerers and recognized as a leader in customer service and quailty. On-time delivery, personal interest in individual projects and "hands-on" quality supervision make Powerfoam one of the most asked for foams in the South Central United States.
Powerfoam will arrange production of special shape foam and insure prompt on-time delivery of all job materials so contractors and plasterers can start work on-time and meet crucial deadlines. All foam is listed with ICBO as approved for exterior insulation on residential and commercial buildings.
Powerfoam also manufactures channeled foam for moisture drainage for all major brands of EIFS.
Return to Index |
 |
 |
Panel Foam
Powerfoam manufactures premium grade and high density expanded polystyrene for the prefabricated building industry.
Residential or commercial, Powerfoam is one of the most recognized foams in the United States for insulated buildings. Powerfoam has been providing foam for structural insulated panels (SIPS) and prefabricated metal buildings for over 15 years and has developed a reputation for outstanding customer service and a quality product.
Powerfoam has been listed/classified/approved by ICBO, FM, UL, and RADCO for construction projects of any size or scope.
Return to Index |
 |
 |
|
Flotation Foam
Powerfoam Floatation Foam is a 1.0 PCF nominal density flame-resistant expanded polystyrene. Powerfoam's flotation foam has a proven track record of quality and performance throughout the South Central United States. Attractive and environmentally safe, Powerfoam EPS flotation is the industry standard for any of these projects:
- Marinas
- Boathouses
- Barges
- Boat Docks
|
- Party Decks
- Pipelines
- Ramps
- Swim Docks
- Fuel Docks
|
Powerfoam EPS flotation will support 50 pounds per cubic foot when fully immersed in water. To estimate the amount of EPS flotation needed for a specific project, estimate three (3) pounds per board foot of lumber to be used building the dock plus 180 pounds per person on the dock at any given time and divide by 50. This figure is the number of cubic feet of EPS flotation necessary to support the structure and its occupants.
|
BLOCK SIZE |
MAXIMUM WEIGHT |
BLOCK SIZE |
MAXIMUM WEIGHT |
| 12" x 48" x 96" (32cu. ft.) |
1600 lbs. |
12" x 48" x 192" (64 cu.ft.) |
3200 lbs. |
| 18" x 48" x 96" (48cu. ft.) |
2400 lbs. |
18" x 48" x 192" (96cu. ft.) |
4800 lbs. |
| 24" x 48" x 96" (64cu. ft.) |
3200 lbs. |
24" x 48" x 192" (128 cu. ft.) |
6400 lbs. |
| 36" x 48" x 96" (96cu. ft.) |
4800 lbs. |
36" x 48" x 192" (192 cu. ft.) |
9600 lbs. |
Return to Index |
 |
|
 |